°CALEONbox Clima
Universal system and individual room controller for surface heating and cooling systems in combination with up to 8 °CALEON Clima room controllers. The continuous dew point control in each room ensures safe and efficient cooling operation.
°CALEONbox Clima | |
---|---|
Temperature control class | VIII / 5% |
Power supply | 230VAC |
Internal operating voltages | 24VDC, 5VDC, 3.3VDC |
Relay outputs 230VAC on/off | 9 |
Relay outputs potential-free with switch contact | 2 |
0-10V or PWM outputs | 3 |
24VDC voltage output for external devices | ✓ max. 6W |
LEDs for operating conditions | 14 |
Temperature sensor inputs *1 | up to 20 |
Grundfos VFS Sensor input *4 | ✕ |
Compatible room controllers *3 | up to 8 °CALEON or °CALEON Clima |
Digital interface *2 | 2xCAN + 1-Wire |
Heating pump *5 | 230VAC on/off or PWM |
Heating mixer *6 | 0-10V or PWM |
Heating zones and actuators *7 | 8 x 3 |
Heat request *8 | ✓ |
Fan coil function via 0-10V/PWM | ✓ |
Heating/cooling switching *8 | ✓ |
Cooling request *8 | ✓ |
Dehumidifiers *9 | ✓ |
Heating operating times per day *10 | 8 per zone |
Comfort function for rapid heating *10 | ✓ for each zone |
Energy-saving heating mode Eco *10 | ✓ for each zone |
Cooling times per day *10 | 8 per zone |
Comfort function for rapid cooling *10 | ✓ for each zone |
Energie-saving cooling mode Eco *10 | ✓ for each zone |
Internet access via SOREL Connect *11 | ✓ |
Dew point calculation *12 | ✓ |
Holiday programme | ✓ |
PID control for constant room temperature | ✓ |
Frost protection function | ✓ |
Circulation pump operation | ✕ |
*1 by 1-wire bus up to 20 sensors. Additional temperature sensors by CAN network
*2 Two separate CAN networks, 1x private (appartment), 1x heating system (building)
*3 up to 8 °CALEON can be supplied with 24VDC by °CALEONbox. When connecting more °CALEONs, an additional power supply is required. Alternatively, an external 230VAC thermostat can be operated for each zone.
*4 for measuring tap temperature and flow for domestic hot water control
*5 via 230VAC relays on/off, or speed-controlled via PWM
*6 Flow temperature control is done according to room temperature, optionally weather-compensated or combination of weather-compensation with room temperature influence
*7up to 8 heating zones with up to 3x 230VAC actuators as NO or NC design also with PID control
*8 potential-free relay contact, 0-10V or PWM signal or via CAN network
*10 adjustable via °CALEON or °CALEON Clima
*11 via SOREL Data Logger (soon also via °CALEON 24VDC Smart Thermostat with Wifi)
*12 separately in every zone where °CALEON Clima is installed
Manuals:
System manual:
Configurator for underfloor heating
Find the right components for controlling your underfloor heating and cooling system with °CALEONbox Clima here.
Where to buy
Find your national SOREL contact person or the nearest SOREL retailer
Find contact person